0 to 14" Water Column Intrinsically Safe Ratiometric Differential Pressure Transducer

Model Number: CS84-AA00014WD2A000-00

CS84 Intriniscally safe differential pressure transducer with 14 Inches Water Column (~0.5 PSI) measurement range and 0.5-4.5V ratiometric and M12x1

CS84-AA00014WD2A000-00 Click to expand image

Specifications Overview

Configured model specifications
Pressure Range0 to 14 Inches WC Differential
Output Signal0.5-4.5V ratiometric
Supply Voltage5VDC, regulated
Electrical ConnectionM12x1
Process Connection1/4" FNPT
Wetted Material316L Stainless Steel
Accuracy @ 25°C (Accuracy includes non-linearity, hysteresis and non-repeatability) ≤ ± 0.50% BFSL
Typical Lead Time2–3 weeks
Country of OriginUSA
Certification
  • CE
  • Class I, Division 1, Groups C, D T4
  • Class I, Zone 0 AEx ia IIB T4 Ga (Ex ia IIB T4 Ga)
  • RoHS