FEATURES

  • CSA Class I, Division 2, Groups A, B, C, D T4 Approved
  • Differential pressures up to 50 PSI
  • Line pressures up to 500 PSI
  • Bi-directional pressure ranges available
  • Assembled in New Jersey, USA

COMMON APPLICATIONS

About the CS54

The CS54 Non-Incendive Differential Pressure Transducer is a high strength sensor designed for differential pressure measurements of liquids and gases in Class I, Division 2 hazardous locations. A 316L SS oil filled sensor element provides excellent stability over a wide operating temperature range while offering corrosion resistance against various liquids and gases. Differential pressure ranges up to 50 PSI are available with 1/4″ MNPT or FNPT process connections.

Caution must be taken when installing and operating the CS54 in known Class I, Division 2 hazardous locations. Please review the Non-Incendive Operating Instructions prior to installation.

Approvals/Certifications

  • CSA Class I, Division 2, Groups A, B, C, D T4
  • ABS (American Bureau of Shipping) Approved
  • CE

Now Available With A Turck Mini-Fast Connection

No Conduit Installation Required!

In an effort to simplify installation in Class I, Division 2 hazardous locations, the CS54 Non-Incendive Differential Pressure Transducer is offered with an integral Turck Mini-Fast electrical connection.

When combined with a Turck cordset (with ITC rated cable) and a Turck Lokfast Guard, there is no requirement for conduit to be installed over the cable*. This not only makes installation easy but also makes switching out sensors less cumbersome. Core Sensors can supply all components as a complete package. Click here to learn more about the Turck Mini-Fast electrical connection.

* Core Sensors recommends confirming hazardous location installation requirements with your local inspector as each installation is unique.

When viewing on a mobile device, swipe or press the arrow to view additional information

Performance

Accuracy*:
≤ ± 0.25% BFSL
≤ ± 0.5% BFSL (2 PSI & below)
Stability (1 Year):
≤ ± 0.25% of FS
Pressure Cycles:
4 million
Max Line Pressure:**
500 PSI
Max Differential Pressure:
50 PSI
Overpressure:***
2X or 500 PSI, whichever is less, rated differential pressure
Burst Pressure:***
3X rated differential pressure

* Accuracy includes non-linearity, hysteresis and non-repeatability
** Max line pressure is the highest common mode pressure that can be applied to the sensor without damage.
*** Overpressure and burst pressure are the maximum differential pressure that can be applied to the high or low side before damage to the sensor will occur.

Thermal

Operating Temperature
-40 to +80°C
Operating Temperature
(Electrical connection “F”, DIN 43650-A)
-20 to +80°C
Media Temperature
-40 to +125°C
Media Temperature
(Electrical connection “F”, DIN 43650-A)
-40 to +105°C
Compensated Temperature
0 to +55°C
Storage Temperature
-40 to +125°C
TC Zero
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI & below)
TC Span
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI & below)

Environmental

EMI/RFI Protection
Yes
IP Rating*
IP65 minimum
Vibration
10g, 20 to 5000Hz
Shock
100g, 11msec, 1/2 sine

* IP Rating is dependent on electrical termination selected. Contact factory for more information.
* IP Rating applies when electrical connector is attached with the appropriate ingress protection.

Electrical (Current)

Outputs
4-20mA
Excitation
10-28VDC
Current Consumption
20mA, typical
Output Load
0-800 Ohms @ 10-28VDC
Frequency Response (min)
~250Hz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Voltage)

Outputs
1-5V
Excitation
10-28VDC
Current Consumption
<10mA Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Ratiometric)

Outputs
0.5-4.5V ratiometric
Excitation
5VDC +/- 0.5V
Current Consumption
<10mA Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Low Power)

Outputs
0.5-2.5V non-ratiometric
Excitation
3-5VDC unregulated
Current Consumption
≤ 3mA
Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Specifications are subject to change without notice

Click image to view larger

Ordering Example: CS54-AA00010PD4H000-00 (1/4″ Female NPT, 316L SS, 0-10 PSI differential, 4-20mA, Turck® Mini-Fast®)
– Not all configurations are available. Our sales team can recommend the closest available configuration based on your requirements.
– Contact Core Sensors for configurations not shown.

Note that dimensions are for reference only. Please contact us if you do not see a dimension listed.

Click image to view larger

Contact our sales team

We are happy to answer your questions. Fill out the form and a member of our sales team will contact you to discuss your requirements. You can also give us a call at (862) 245-2673.