You are here: Home1 > Products2 > Hazardous Location3 > CS81 Intrinsically Safe Low Pressure Transducer
CSA Class I, Division 1, Groups C, D T4 Approved
CS81 Series
**Disclaimer: Unless otherwise agreed in writing, Core Sensors products are not authorized for use in applications including medical devices, life support systems, in-flight aerospace, nuclear or any other application where the product failure could result in personal injury or death.
Designed for Low Pressure Measurement Applications
The CS81 Intrinsically Safe Low Pressure Transducer is a high strength sensor designed for low pressure measurements in intrinsically safe areas. The CS81 features an all welded stainless steel construction for a minimum IP65 rating. A wide range of configurable options makes the CS81 a versatile pressure transducer that can be designed to operate in some of the harshest conditions. Low power outputs are available which can operate off of 3-5VDC of unregulated power to extend battery life in remote applications. The CS81 is an excellent solution for applications such as external fuel tank monitoring, vapor recovery and natural gas compression.
Caution must be taken when installing and operating the CS81 in known Class I, Division 1 hazardous locations. Please review the Intrinsically Safe Operating Instructions prior to installation.
Plug and Play Installation
Core Sensors offers a variety of high quality accessories to bundle with the CS81 Intrinsically Safe Low Pressure Transducer to simplify installation.
Common accessories include:
View more accessories here.
Accuracy @ 25°C*
≤ ± 0.25% BFSL
≤ ± 0.5% BFSL (2 PSI & below)
≤ ± 1% BFSL (Millivolt output signal)
Stability (1 Year)
≤ ± 0.25% of FS
Pressure Cycles
100 million
Overpressure
2X minimum
Burst Pressure
5X or 245 PSI, whichever is less
* Accuracy includes non-linearity, hysteresis and non-repeatability
Operating Temperature
-40 to +80°C
Operating Temperature
(Electrical connection “F”, EN175301-803 Form A)
-20 to +80°C
Media Temperature
-40 to +125°C
Media Temperature
(Electrical connection “F”, EN175301-803 Form A)
-40 to +105°C
Compensated Temperature
-15 to +65°C
Storage Temperature
-40 to +125°C
TC Zero
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI & below)
TC Span
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI & below)
EMI/RFI Protection
Yes
IP Rating*
IP65 minimum
Vibration
10g, 20 to 2000Hz
Shock
100g, 11msec, 1/2 sine
* IP Rating is dependent on electrical termination selected. Contact factory for more information.
* IP Rating applies when electrical connector is attached with the appropriate ingress protection.
Outputs
4-20mA
Excitation
10-28VDC
Current Consumption
20mA, typical
Output Load
0-800 Ohms @ 10-28VDC
Frequency Response (min)
~250Hz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max
Outputs
1-5V
1-6V
Excitation
10-28VDC
Current Consumption
<10mA
Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max
Outputs
0.5-4.5V ratiometric
Excitation
5VDC +/- 0.5V
Current Consumption
<10mA
Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max
Outputs
0.5-2.5V non-ratiometric
Excitation
3-5VDC unregulated
Current Consumption
≤ 3mA
Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max
Outputs
10mV/V
Excitation
5VDC, typical
Current Consumption
< 5mA
Output Load
>1M Ohms
Frequency Response (min)
~5kHz
Zero Offset (of FS)
≤ ± 2%
Span Tolerance (of FS)
≤ ± 2%
Specifications are subject to change without notice
Not all configurations are available. Our sales team can recommend the closest available configuration based on your requirements.
Contact Core Sensors for configurations not shown.
Ordering Examples:
Note: Mobile users can use the zoom feature to view the model number configuration matrix clearly.
Note that dimensions are for reference only. Please contact us if you do not see a dimension listed.
Note: Mobile users can use the zoom feature to view the dimensions clearly.
Do you have questions regarding the CS81 intrinsically safe pressure transducer? Need a quote? We are ready to help! Fill out the form and a member of our sales team will contact you to discuss your requirements. You can also give us a call at (862) 245-2673.
CS10 Industrial Pressure Transducer Wide variety of materials, outputs, and connections with pressures from vacuum up to 45,000 PSI
CS10T Pressure Temperature Transducer Independent pressure and temperature outputs from one transducer
CS11 Compact OEM Pressure Sensor Small-footprint OEM sensor built for embedded designs
CS-SM Steel Mill Pressure Transducer Heavy-duty transducer built for steel mill hydraulic systems
CS20 Industrial Temperature Transmitter Compact industrial RTD temperature transmitter with 4-20mA or voltage outputs
CS14 Differential Pressure Transducer General-purpose OEM DP transducer, non-hazardous, from 0.5 PSID to 1,000 PSID
CS54 Non-Incendive Differential Pressure Transducer Class I Div 2 rated DP, 0.5 to 1,000 PSID, for filtration and flow
CS64 Explosion-Proof Differential Pressure Transducer Class I Div 1 Ex-proof DP, 0.5 to 1,000 PSID, for filtration and flow
CS84 Intrinsically Safe Differential Pressure Transducer Class I Div 1 IS rated DP, 0.5 to 1,000 PSID, for hazardous areas
CS12 Submersible Pressure Transducer IP68 submersible transducer for water level monitoring
CS15 Non-Clogging Submersible Pressure Transducer Flush-diaphragm submersible transducer for wastewater level
CS82 Intrinsically Safe Submersible Pressure Transducer IS submersible transducer for fuel and hazardous-liquid level
CS20 Industrial Temperature Transmitter Compact industrial RTD temperature transmitter with 4-20mA or voltage outputs
CS10T Pressure Temperature Transducer Measure pressure and temperature from a single transducer
CS60 Explosion-Proof Pressure Transducer Class I Div 1 Ex-proof, 50–30,000 PSI, optional temp output
CS80 Intrinsically Safe Pressure Transducer Pressures from 50 PSI up to 30,000 PSI in intrinsically safe areas
CS81 Intrinsically Safe Low Pressure Transducer Pressures from 1 PSI up to 49 PSI for pressure and external level measurement
CS82 Intrinsically Safe Submersible Pressure Transducer IS submersible transducer for fuel and hazardous-liquid level
CS84 Intrinsically Safe Differential Pressure Transducer Class I Div 1 IS rated DP, 0.5–1,000 PSID, for hazardous areas
1/4″ SAE Female Schrader to NPT Adapter All stainless steel adapter in stock and ready to ship
1/4" NPT Cooling Adapter All 316L stainless steel adapters in stock and designed for applications with extreme temperatures
Mating Connectors Get your pressure transducer connected with in-stock mating connectors
Vent Tube Breather Plug Vent tube protection from moisture and humidity
Mating Cable Assemblies Mating cordsets and cable assemblies in stock and ready to ship for plug and play operation