CS15

Non-Clogging Submersible Pressure Transducer

FEATURES

  • Pressures from 2 PSI up to 50 PSI
  • Heavy duty steel cage assembly
  • Flush diaphragm prevents clogging
  • Hastelloy C276 diaphragm standard
  • Assembled in New Jersey, USA

COMMON APPLICATIONS

  • Wastewater lift stations
  • Liquid level measurement
  • Tanks with viscous media
  • Turbulent tanks

About the CS15

The CS15 Non-Clogging Submersible Pressure Transducer is designed for liquid level measurement in turbulent tanks and tanks with viscous medias such as wastewater lift stations. A Hastelloy C276 diaphragm, stainless steel construction and an ETFE cable jacket allow for installation in a wide variety of liquids. The heavy duty steel cage anchors the sensor at the bottom of the tank to ensure accurate level readings as well as acting as a barrier between solids in the tank and the flush diaphragm of the sensor. A vent tube runs the length of the cable and quickly equalizes the barometric pressure within the sensor body. The CS15 is available in various output signals including 4-20mA for long distance transmissions and voltage outputs for low power, low current consumption applications.

Approvals/Certifications

1
2
3
4
1

A flush diaphragm in Hastelloy C276 material prevents clogging while also surviving in some of the toughest environments.

2

A Kynar strain relief with Viton seals help prevent liquids from entering the sensor.

3

High corrosion resistance and superior strength make ETFE (Ethylene tetrafluoroethylene) an excellent cable jacket material for the CS15’s most common applications.

4

High strength 304 SS construction makes up the majority of the metallic construction including the heavy duty steel cage, housing (case), and 1/2″ MNPT conduit fitting.

Engineered For The Toughest Environments

The CS15 Non-Clogging Submersible Pressure Transducer was carefully engineered to withstand some of the toughest environments. With a thickness of 1 to 1.5 mils, the diaphragm is the thinnest component of the transducer. To help protect this critical component, Hastelloy* C276 (UNS N10276) is the standard diaphragm material. This material is a super nickel-molybdenum-chromium alloy offering excellent corrosion resistance, prolonging the life of the transducer.

300 series stainless steel (316L and 304) make up the remaining metallic construction including the heavy duty steel cage, housing (case), and 1/2″ MNPT conduit fitting. Precision tig welds along with a Kynar strain relief and Viton seals prevent liquids from entering the sensor, resulting in an IP68 rating.

A high quality ETFE cable jacket exits the sensor, allowing for long term submersion in a wide variety of liquids.

*Hastelloy® is a registered trademark of Haynes International, Inc.

When viewing on a mobile device, swipe or press the arrow to view additional information

Performance

Accuracy @ 25°C*
≤ ± 0.25% BFSL
≤ ± 0.5% BFSL (2 PSI)
Stability (1 Year)
≤ ± 0.25% of FS
Pressure Cycles
50 million
Overpressure
2X minimum
Burst Pressure
5X or 250 PSI, whichever is less

* Accuracy includes non-linearity, hysteresis and non-repeatability

Thermal

Operating Temperature
-40 to +85°C
Compensated Temperature
0 to +55°C
Storage Temperature
-40 to +125°C
TC Zero
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI)
TC Span
≤ ± 1% of FS
≤ ± 2% of FS (2 PSI)

Environmental

EMI/RFI Protection
Yes
IP Rating
IP68
Vibration
10g, 20 to 2000Hz
Shock
100g, 11msec, 1/2 sine

Physical

Weight, excluding cable (approx.)
3.50 lb.
Wetted Material
See Dimensions/Materials listing
Cable Conductors
22 AWG
Cable Pull Strength
150 lb.

Electrical (Current)

Outputs
4-20mA
Excitation
10-28VDC
Current Consumption
20mA, typical
Output Load
0-800 Ohms @ 10-28VDC
Frequency Response (min)
~250Hz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Voltage)

Outputs
1-5V
Excitation
10-28VDC
Current Consumption
<10mA Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Ratiometric)

Outputs
0.5-4.5V ratiometric
Excitation
5vDC +/- 0.5V
Current Consumption
<10mA Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Electrical (Low Power)

Outputs
0.5-2.5V non-ratiometric
Excitation
3-5VDC unregulated
Current Consumption
≤ 3mA
Output Load
5K Ohms, min
Frequency Response (min)
~1kHz
Zero Offset (of FS)
≤ ± 0.5% typical, ± 1% max
Span Tolerance (of FS)
≤ ± 0.5% typical, ± 1% max

Specifications are subject to change without notice

Click image to view larger

Ordering Example: CS15-7C00010PG4Z000-16 (Steel cage, Hastelloy C276, 0-10 PSI gauge, 4-20mA, 1/2” MNPT conduit w/ Kynar strain relief, 16 meter cable)
– Not all configurations are available. Our sales team can recommend the closest available configuration based on your requirements.
– Contact Core Sensors for configurations not shown.

Note that dimensions are for reference only. Please contact us if you do not see a dimension listed.

Click image to view larger

Click image to view larger

Installation Methods

There are various installation methods that can be used when monitoring level with a pressure transducer. Core Sensors offers both submersible and externally mounted sensors designed for continuous level measurement of vented and sealed tanks.

Contact our sales team